Follow

GET THE DOUBLE OF THE NOMINAL POWER

Diesel fuel injection pumps SPP Series produced by DETEQ are equipped with an exclusive system for power control which allows to obtain, for 3 consecutive minutes, the twice the installed engine nominal power.

EXAMPLE

Engine with power 5,5kW >> 11kW for 3 minutes: the sufficient time for a flow test with a test cycle of 1000 shots

STANDARD PRODUCTION MODELS

STANDARD PRODUCTION MODELS

8 cylinder version available in the following powers:

  • 5,5 kW ( 7,5HP)
  • 7,5kW (10HP)
  • 9,2 kW (12,5HP)

12 cylinder version available in the following powers:

  • 5,5 kW ( 7,5HP)
  • 7,5 kW (10HP)
  • 11 kW (15HP)

 

SPP TEST BENCH TECHNICAL FEATURES

ITEM SPECIFICATION
DRIVE MOTOR AC 220-380V/3P/ 50-60Hz, 4 pole induction motor (control by inverter)
SPEED RANGE 0 - 3500 rpm in both directions
PUMP MOTOR AC 3ph 0,75 KW ( 1HP ) 4 pole induction motor
PUMP Max output pressure 6MPA ( working pressure: 0÷5 BAR )
Max output flow 9 l/min Vane pump
FUEL TANK 40 liters working capacity
TEMPERATURE CONTROL Variable from 40° +/- 2°  with display 0-99,9°C
HEATER AC 220V   0,8KW
SPEED CONTROL Adjustable from ZERO to MAX through 2 steps ( accurate and quick )
GLASS 260cc and 44cc both sides 
STROKE COUNTER 0 - 1000 in steps of 50 turns   
RPM COUNTER 4 digit 7 segment LED display ( 0-9999 rpm indication) with accuracy 0,1%
VM.VE ( ROTARY) FUEL CONTROL VALVE 0,2 ÷ 2 BAR supply pressure control
LOW (PE. IN LINE) FUEL CONTROL VALVE 0,5 BAR  supply pressure control
PE.A( IN LINE ) / VM.VE ( ROTARY) PRESSURE GAUGE Ø 100   -1/0/5 BAR with glycerol
TRANSFER PRESSURE GAUGE Ø 100    0 ÷ 16 BAR with glycerol
OVERFLOW PRESSURE GAUGE Ø 100    0 ÷ 1,6 BAR with glycerol
HIGH PRESSURE GAUGE Ø 100    0 ÷ 60 BAR with glycerol
GOVERNOR PRESSURE GAUGE ( LDA ) Ø 100    0 ÷ 2,5 BAR with glycerol
VACUUM REGULATOR For test the feeder system
AIR REGULATOR 0÷2,5BAR
RACK SCALE On request
FILTERING SYSTEM 2 levels 10 - 5 micron
FLYWHEEL Ø 420 mm with increments each 0,5° for high accuracy timing FIP
INERTIA 1 Kgm2
CENTER HEIGHT 125mm     guide 20mm
CENTER HEIGHT AND AXES DEVIATION
+/- 0,02 mm
OVERLOAD CAPACITY 200% for 3 minutes
POWER SAVING SYSTEM 40%
ANTI-BACKLASH COUPLING with protection cover
NOICE EMISSION Low
HIGH TORQUE CAPACITY 108 Nm constant till 1050 RPM
ISO RULES Comply with ISO 4008/1 and  ISO 4008/2
DRIVING CAPACITY FIP Up to 600 mm3 / injection / cylinder
AIR CONNECTION 1/4 GAS   2÷10BAR
FREE MAINTENANCE
EASY TO USE
SAFETY FOR THE USER
PACKING DIMENSION AND WEIGHT mm 2000 x 1000 x 2000h   -   400 Kg
NET WEIGHT 800 Kg

Additional information is available on the website http://open.deteq.com/catalog2013/index.html#/30/#/30/